The results of instrumental measurements of parameters of electromagnetic fields in the frequency range 5Hz-400kHz
Object name: | Apartment (new building) |
The actual address of the object: | ....... |
Contact number: | ........... |
Name of the legal entity: | .......... |
.......... | |
Object division: | Vimyryuvannya in new apartments |
A source: | LEP 330kV 37-40m. |
Date Time
Regulations
The electric zones of the electric modezh will be installed:
uzdovzh povіtryanih lіnіy elektroperedachі - at viglyadі zemelnoї dіlyanki i povіtryanogo spaciousness, obmezhenih vertical ploschinami scho vіddalenі of the Parties obidvі lіnії od kraynіh provodіv for Minds nevіdhilenogo їh position on vіdstan:
(for the povitrynikh lіnіy in the spring)
2 meters - up to 1 kV
10 meters - up to 20 kV
15 meters - 35 kV
20 meters - 110 kV
25 meters - 150, 220 kV
30 meters - 330, 400, 500, + (-) 400 kV
40 meters - 750 kV;
"THE RULES OF THE OCHORONI ELECTRIC MEANS" HAS BEEN FIRED BY THE RESOLUTION OF THE CONSTRUCTIVE MINISTRY OF UKRAINE VID 4 BARRECH 1997 р. N 209
Property Details:
aerial location
the minimum distance to the support - 37 m
Meter Information:
The measurements were carried out using a three-component “VE-meter-AT-003” Magnetic and Electric Field Parameter,
registered in the State Register of Measuring Instruments under the ........
Gauge serial number: ........
Certificate of verification № .......
Valid until: 04.09 ......
Checking date: 09.08 .......
Measurement error:
- relative error of measurement of mean-square values of electric field intensity ± 15%
- relative error of measurement of mean-square values of magnetic field strength ± 15%
Number of monitored controlled areas: 3
KZ №1-Kitchen.
CZ number 2-small room.
CZ number 3-Large room.
Measurement results | ||||||||||||||
Duration of one measurement, min: 5 | ||||||||||||||
Number of measurement | Measured Parameters | Height measurements | ||||||||||||
B I-50, μT | BII, ntl | B50, µT | E I-50, B / m | EII, B / m | E50, B / m | |||||||||
* | ** | * | ** | * | ** | * | ** | * | ** | * | ** | |||
one | 0.029 | 0.033 | 1.64 | 1.89 | 0.166 | 0.191 | 1,3 | 1.5 | 0.322 | 0.37 | 31.3 | 36 | 0.5-1.5m | |
2 | 0.025 | 0.029 | 1.67 | 1.92 | 0.16 | 0.184 | 0.5 | 0.575 | 0.322 | 0.37 | 34,8 | 40 | 0.5-1.5m | |
3 | 0.026 | 0.03 | 1.57 | 1.81 | 0.142 | 0.163 | 2 | 2.3 | 0.32 | 0.368 | 47.2 | 54.3 | 0.5-1.5m |
BI-50, EI-50: induction of the MP and the intensity of the EP in the 1m frequency sub-band (5 Hz-2 kHz) minus the industrial frequency (50 Hz),
BII, EII: MP induction and electric field intensity in the 2nd frequency sub-band (2 kHz-400 kHz),
B50, E50: MP induction and industrial frequency (50 Hz) electric field intensity
* - average values of measured EMF values
** - taking into account the error of the Meter
Conclusion (does not replace the expert opinion):
The MP radiation from a PC in the 1m frequency sub-band (5Hz-2kHz) without industrial frequency MPs (50Hz) does not exceed the standard value of 0.25 μT.
The radiation of a PC MP in the 2m frequency subband (2 kHz-400 kHz) does not exceed the standard value of 25 nT.
Radiation MP industrial frequency (50 Hz) does not exceed the standard value of 5 mT.
The EP radiation from a PC in the 1m frequency range (5Hz-2kHz) without the industrial frequency EP (50Hz) does not exceed the standard value of 25V / m.
The emission of an electron beam from a PC in the 2m frequency sub-band (2 kHz-400 kHz) does not exceed the standard value of 2.5 V / m.
The emission of industrial frequency (50 Hz) EP does not exceed the standard value of 500 V / m.
Measurements conducted:
Position | Full name | ⁄ .............. ⁄ |
The measurements were carried out in the presence of:
Customer: | ⁄ ................ ⁄ |